site stats

Greenheck unit heaters

WebFEATURES OF AN M-SERIES MAU UNIT: 100% Combustion Efficiency Up to 6,500 MBH Capacity Up to 75,000 CFM Natural Gas or Propane Shielded and ventilated motor assembly Low voltage hot surface igniter Closed cell, non-water absorbing insulation in the base to eliminate condensation issues WebAs the worldwide leader in manufacturing high quality air movement, control and conditioning products, Greenheck offers the most comprehensive line of ventilation … Grilles, registers and diffusers cover supply or return openings for HVAC systems. … A direct drive, inline-mounted fan designed for exhaust supply or return air … The GRSI is a spun aluminum air relief roof ventilator for natural gravity or positive … In variable air volume (VAV) systems, the flow of air is supplied by a single air … The USGF is a belt drive fan ideal for heavy grease exhaust applications where …

Cabinet Unit Heater Horizontal and Vertical Daikin Applied

WebGreenheck’s model ERT combines the benefits of the total energy wheel with supplemental cooling and/or heating. The result is a unit that is specifically designed to be the most efficient product for conditioning humid outdoor air to near room conditions. Model ERT provides excellent humidity control without over cooling and WebJul 1, 2024 · 1 Jul 2024. Greenheck’s latest electric duct heater, model IDHE-O with a NEMA 4 enclosure, is UL listed for outdoor applications. The IDHE-O allows for multiple mounting positions where the control cabinet can be installed on either side of a horizontal duct or in any orientation on a vertical duct. The control cabinet is offset from the ... bwilso https://myorganicopia.com

Products Greenheck

WebOffered in 16 models with heating capacities ranging from 5,119 to 16,380 Btu per hour, these electric unit heaters are lightweight and compact—all units weigh less than 30 pounds, and the grille-and-frame assembly measures approximately 21 inches high, 16 inches wide and 5 inches deep (including the rough-in-box). WebWhat's New. Sterling introduces the Nexus unit heater, a leading-edge condensing heat exchanger delivering up to 97% efficiency. Featuring a single-stage, two-stage or full modulation firing rate, this durable 316L stainless steel heat exchanger is available with both natural gas and LP gas flexibility (also field-convertible to separate combustion). WebGreenheck is the leading supplier of air movement and control equipment that includes fans, dampers, louvers, kitchen ventilation hoods, and energy recovery and make-up air … bwi local time

Direct Fired Gas Heated Make Up Air Unit Operation

Category:Trane Index

Tags:Greenheck unit heaters

Greenheck unit heaters

Cabinet Unit Heater Horizontal and Vertical Daikin Applied

WebDesigned to replace exhausted air in commercial, industrial and kitchen applications with options to heat, ventilate, cool, humidify, dehumidify, and filter air. LEARN MORE DEDICATED OUTDOOR AIR SYSTEMS … WebUnit Heaters When its cold outside, Reznor brings the heat. For more than 90 years, we’ve delivered reliable, high-efficiency unit heaters to our customers. Our unit heaters feature attractive, high-gloss exteriors, …

Greenheck unit heaters

Did you know?

WebGreenheck’s direct gas technology uses direct gas-fired line burners with capacities up to 4,800,000 BTU/hr to provide efficient heating in any climate. A 92% thermal efficiency reduces gas consumption for maximum energy savings for both natural gas and propane fuel sources. Features Benefits Webideal make-up air unit where gas-fired heating is not desired. Coil heating and/or cooling tempering options are available with airflow volumes up to ... For exact air performance data based on specific unit configuration, use the Greenheck CAPS selection program. 6 Air Performance Housing Size 12 Blower Size CFM Total Pressure in inches wg 0. ...

WebFor unit-specific information, refer to the Installation, Operation and Maintenance manual (IOM) for the unit in which this furnace is installed. • Both the furnace units are listed for … Webwww.greenheck.com Product Specification Guide Model IDHB, IDHE, IDHE-O Series Duct Heaters Facility Service Subgroup: 23 82 33 – Electric Duct Heaters ... IDHB / IDHE: Unit mounted control panel and cover shall be constructed of heavy gauge minimum G60 galvanized steel with multiple knockouts for field wiring.

WebReznor® model UBX gas-fired unit heaters are great for space heating applications. These units are power vented to eliminate heat losses up the flue pipe. UDX and UBX models are available in 14 sizes ranging from 30,000 to 400,000 BTUH gas input and are approved for installation in the United States and Canada by ETL.

WebTrust Greenheck for quality new and replacement Conversion Parts for Tempered Air Products. In-stock parts ship the same day! Free shipping over $25. ... Heater, Caseys 30Kw 208/3 26X15 3 Stage, Product # 459040: Consult Factory Add to Compare List: 465574 Model ...

Webadvantages of direct fired gas heaters include: •Low cost per BTU of heating •Readily available •Most efficient heat transfer There are two general types of gas-fired heaters, direct and indirect. Indirect fired heaters, like a residential furnace, burn gas inside a metal tube called a heat exchanger. The air that is used to bwi london flightsWebGreenheck’s indirect gas technology uses 80% efficient tubular-style heat exchangers with capacities up to 1,200,000 BTU/hr to provide efficient heating in any climate. Single, … cfa aneurysm repairWebTrane Index bwi locationWebThe IDHE is a universal duct heater that eliminates the need for right- and left-handed designs. The IDHE has the following features: Six mounting positions with vertical up and down flow Rotation to fit the requirements and location of the HVAC system Standalone duct heater capability Lower standard heater wire watt density and higher duct to heat … cfa angioplastyWebA complete line of curb products for mounting Greenheck rooftop equipment. Curb products safely support rooftop equipment while maintaining a leak-proof interface between the building and HVAC equipment. Standard Curbs Standard curbs support a majority of rooftop equipment and exhaust/supply fans. cfa andre siegfriedWebAir Conditioning Greenheck Products Air Conditioning AIR CONDITIONING Heating, cooling and dehumidifying air for comfort and energy savings. The variety of energy-efficient air conditioning products ensure optimal temperatures and humidity levels that keep occupants comfortable and employees productive. MAKE-UP AIR b. wilsonWeb2-pipe applications, up to 150 psig steam or 220 psig, 375°F water. Copper coils, 1/2" diameter, with aluminum fins (12 per inch) Horizontal louvers standard, vertical louvers an option on all models. Intermittent or continuous fan operation controls (optional) Standard 115/60/1 PSC motors, enclosed with thermal overload protection. bwi.lostand found tsa.dhs.gov